Especially produced for implant application in medical activity.

Detailed product properties
Color: 
white
Electrically insulator: 
Yes
Felhasználási terület: 

Rods

Diameter

[mm]
Tolerance on diameter

[mm]
Weight

[kg/m]
Standard length

[mm]
Tolerances on length

%
Stock shape /
Can be ordered
Color
12.7 +0.1 +1.2 0.081 1000 0 +3 Stock shape white
20 +0.2 +1.2 0.317 1000 0 +3 Stock shape white
40 +0.2 +1.5 1.24 1000 0 +3 Stock shape white
45 +0.3 +2.0 1.57 1000 0 +3 Stock shape white
50 +0.3 +2.0 1.95 1000 0 +3 Stock shape white
55 +0.3 +2.0 2.289 1000 0 +3 Stock shape white
60 +0.3 +2.3 2.8 1000 0 +3 Stock shape white
65 +0.3 +2.5 3.269 1000 0 +3 Stock shape white
70 +0.3 +2.5 3.8 1000 0 +3 Stock shape white
75 +0.4 +3.0 4.355 1000 0 +3 Stock shape white
80 +0.4 +3.0 4.947 1000 0 +3 Stock shape white
83 +0.4 +3.0 5.19 1000 0 +3 Stock shape white
88 +0.5 +3.4 5.83 1000 0 +3 Stock shape white
90 +0.5 +3.4 6.264 1000 0 +3 Stock shape white
100 +0.6 +3.8 7.728 1000 0 +3 Stock shape white
Stock shape means that product is regularly produced. You should ask for the current stocks on request.
Product properties
PropertiesUnitMethodValue
Colourwhite
Densityg/cm3DIN EN ISO 11830.93
Flammability (UL94)-DIN IEC 60695-11-10HB
Water absorption in air, 24 h / 96 h, (23ºC)%DIN EN ISO 62<0.01
Dielectric constant-IEC 602502.3
Volume resistivityΩ*cmIEC60093>1014
Surface resistivityΩIEC60093>1014
Dielectric strengthkV/mmIEC 6024345
Dielectric dissipation factor (50 Hz)-IEC60 2500.0001
Comparative tracking index (CTI)-IEC 60112600
Thermal conductivityW/ (K.m)ISO 22007-4:20080.4
Chemical resistance at 23ºC: deluted acids-A
Chemical resistance at 23ºC: strong acids-A
Chemical resistance at 23ºC: aliphatic hydrocarbons-B
Chemical resistance at 23ºC: chlorin dissolvents-B
Chemical resistance at 23ºC: alcoholsA
Chemical resistance at 23ºC: deluted bases-A
Chemical resistance at 23ºC: strong bases-A
Chemical resistance at 23ºC: aromatic hydrocarbons-B
Melting temperatureºCISO 11357-3135
Glass transition temperatureºCDIN 53765
Specific heatJ/(g.K)ISO 22007-4:20081,9
Coefficient of linear thermal expansion (CLTE): 23 - 60ºCm/(m.K)x10-5DIN EN ISO 11359-1;2150
Coefficient of linear thermal expansion (CLTE): 23 - 100ºCm/(m.K)x10-5DIN EN ISO 11359-1;2230
Max. allowable service temperature in air, short termºC130
Max. allowable service temperature in air, long termºC80
Min. allowable service temperature in air, long termºC- 250
Heat deflection temperatureºCDIN EN ISO 75, A79
Yield stressMPaDIN EN ISO 527-220
Modulus of elasticity (tensile test)MPaDIN EN ISO 527-2680
Elongation at break%DIN EN ISO 527-2>200
Flexural strengthMPaDIN EN ISO 178
Impact strength, CharpykJ/m2DIN EN ISO 179-1eU
Tensile strengthMPaDIN EN ISO 527-2
Compressive strengthMPaEN ISO 604 1% / 2%
Notched impact strength, charpykJ/m2DIN EN ISO 179-1eAnem törik
Ball indentation hardnessMPaISO 2039-1
Shore D hardness-DIN EN ISO 86863