Detailed product properties

Inductively detectable. POM C base matrix with detectable filler. Good toughness and strength. Good resistance to cleaning agents.

Color: 
grey, blue
Electrically insulator: 
Yes
Felhasználási terület: 

Available product types

Rods

Diameter

[mm]
Tolerance on diameter

[mm]
Weight

[kg/m]
Standard length

[mm]
Tolerances on length

%
Stock shape /
Can be ordered
Color
30 +0.2 +1.0 1.12 1000, 3000 0 +3 Can be ordered grey
Stock shape means that product is regularly produced. You should ask for the current stocks on request.

Plates

Thickness

[mm]
Tolerances on thickness

[mm]
Weight

[kg/m]
Size of plate

[mm]
Tolerances on width

[mm]
Tolerances on length

%
Stock shape /
Can be ordered
Color
25 +0.5 +2.5 16.36 500 x 3000 +5 +25 0 +3 Stock shape blue
Stock shape means that product is regularly produced. You should ask for the current stocks on request.
Product properties
PropertiesUnitMethodValue
Colourgrey, blue
Densityg/cm3DIN EN ISO 11831.49
Flammability (UL94)-DIN IEC 60695-11-10HB
Water absorption in air, 24 h / 96 h, (23ºC)%DIN EN ISO 620.05/ 0.1
Dielectric constant-IEC 60250
Volume resistivityΩ*cmIEC600931013
Surface resistivityΩIEC600931013
Dielectric strengthkV/mmIEC 60243
Dielectric dissipation factor (50 Hz)-IEC60 250
Comparative tracking index (CTI)-IEC 60112
Thermal conductivityW/ (K.m)ISO 22007-4:20080.39
Chemical resistance at 23ºC: deluted acids-B
Chemical resistance at 23ºC: strong acids-C
Chemical resistance at 23ºC: aliphatic hydrocarbons-A
Chemical resistance at 23ºC: chlorin dissolvents-B
Chemical resistance at 23ºC: alcoholsA
Chemical resistance at 23ºC: deluted bases-A
Chemical resistance at 23ºC: strong bases-A
Chemical resistance at 23ºC: aromatic hydrocarbons-A
Melting temperatureºCISO 11357-3169
Glass transition temperatureºCDIN 53765-60
Specific heatJ/(g.K)ISO 22007-4:20081.3
Coefficient of linear thermal expansion (CLTE): 23 - 60ºCm/(m.K)x10-5DIN EN ISO 11359-1;213
Coefficient of linear thermal expansion (CLTE): 23 - 100ºCm/(m.K)x10-5DIN EN ISO 11359-1;214
Max. allowable service temperature in air, short termºC140
Max. allowable service temperature in air, long termºC100
Min. allowable service temperature in air, long termºC- 30
Heat deflection temperatureºCDIN EN ISO 75, A
Yield stressMPaDIN EN ISO 527-268
Modulus of elasticity (tensile test)MPaDIN EN ISO 527-23200
Elongation at break%DIN EN ISO 527-210
Flexural strengthMPaDIN EN ISO 178100
Impact strength, CharpykJ/m2DIN EN ISO 179-1eU59
Tensile strengthMPaDIN EN ISO 527-268
Compressive strengthMPaEN ISO 604 1% / 2% 17 / 31
Notched impact strength, charpykJ/m2DIN EN ISO 179-1eA11
Ball indentation hardnessMPaISO 2039-1174
Shore D hardness-DIN EN ISO 868